完整后设资料纪录
DC 栏位 | 值 | 语言 |
---|---|---|
dc.contributor.author | 林雍杰 | zh_TW |
dc.contributor.author | 蔡春进 | zh_TW |
dc.contributor.author | LIN,YUNG-JIE | en_US |
dc.contributor.author | Tsai, Chuen-Jinn | en_US |
dc.date.accessioned | 2018-01-24T07:38:30Z | - |
dc.date.available | 2018-01-24T07:38:30Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.uri | http://etd.lib.nctu.edu.tw/cdrfb3/record/nctu/#GT070351715 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/139863 | - |
dc.description.abstract | 二阶静电集尘器广泛的应用于餐厅做为废气处理设备,但其去除效率及理论模式却鲜少受到检视与探讨。有鉴于此,本研究将对一台额定风量为1000 CFM的市售静电集尘器进行测试,测试项目包括:不同风量下(4 CMM~30.75 CMM)的PM2.5收集效率、臭氧副产物的浓度及PM2.5收集效率随时间的变化,及建立二阶静电集尘器收集效率的理论模式。 实验结果显示,当风量从4 CMM上升至30.75 CMM时,油烟微粒的质量中间气动直径(MMAD, mass median aerodynamic diameter)会由0.44 µm降至0.2 µm,PM2.5收集效率则由96.3 %降为43.9 %。此结果显示收集效率随着风量上升而下降,与该厂商声称的适用风量1000 CFM(28.32 CMM)有很大的落差。另外,在10 CMM的风量下,使用高浓度油烟微粒对静电集尘器进行长时间的效率测试,产生总油烟微粒质量浓度为1609.3 µg/m3、质量中间气动直径为0.5 µm,累积使用141小时后,PM2.5的收集效率由91%降至61%,而总负载微粒重量为 104.7克。 为了建立二阶静电集尘器的收集效率模式,本研究将二阶静电集尘器视为充电端与收集端的串联,分别计算各粒径的油烟微粒在充电端与收集端的收集效率,再计算出二阶静电集尘器的总体收集效率。计算的结果显示,二阶静电集尘器的总体收集效率会随风量的上升而下降。将模式计算的结果与实验的实测值进行比对,结果显示在测试风量范围中,最大误差皆不大于10%,与实测值相当吻合。 | zh_TW |
dc.description.abstract | Two-stage electrostatic precipitators (ESPs) are commonly used in restaurants as exhaust gas treatment equipment, but only few studies have investigated the theoretical and experimental collection efficiency. A commercial two-stage ESP was tested in this study. Test items include: collection efficiency of fine particles at different flow rates, concentration of ozone by-products, and changes of collection efficiency of fine particles with time. When increasing the flow rate from 4 CMM to 30.75 CMM, the mass median aerodynamic diameter (MMAD) of generated oil fume decreased from 0.44 µm to 0.2 µm and PM2.5 collection efficiency also decreased from 96.3 % to 43.9 %. A long time exposure test also conducted at the flow rate of 10 CMM in this study, after 141 hours of exposure, 104.7g of particles were collected in ESP and the corresponding PM2.5 collection efficiency decreased from 91 % to 61 %. In order to build the collection efficiency model, two-stage ESPs are seen as a series connection of ionizing section and collector section, and the collection efficiency of each part are calculated separately. According to the model result, collection efficiency of the two-stage ESP is inversely proportional to the operating flow rate. The model was compared with experimental data. Result shows that model can fit experimental data quite well, error at all operating flow rate is less than 10 %. | en_US |
dc.language.iso | zh_TW | en_US |
dc.subject | 二阶静电集尘器 | zh_TW |
dc.subject | 静电集尘器 | zh_TW |
dc.subject | 油烟 | zh_TW |
dc.subject | PM2.5 | zh_TW |
dc.subject | Electrostatic Precipitator | en_US |
dc.subject | Oil Smoke | en_US |
dc.title | 一个二阶静电集尘器的PM2.5油烟去除效率的实验及理论研究 | zh_TW |
dc.title | Experimental and Theoretical Studies of the PM2.5 Oil Smoke Collection Efficiency of a Two-Stage Electrostatic Precipitator | en_US |
dc.type | Thesis | en_US |
dc.contributor.department | 环境工程系所 | zh_TW |
显示于类别: | Thesis |