Title: Effects of RCA clean-up procedures on the formation of roughened poly-Si electrodes for high-density DRAMs' capacitors
Authors: Liu, HW
Lai, WK
Yu, SY
Huang, SC
Cheng, HC
電子工程學系及電子研究所
Department of Electronics Engineering and Institute of Electronics
Keywords: RCA clean-up procedures;poly-Si electrodes;high-density Drams' capacitors
Issue Date: 1-Nov-1997
Abstract: A novel structure, the phosphorus-implanted poly-Si films treated with phosphoric acid (H3PO4) and cleaned by standard RCA cleanup procedures, has been demonstrated as the bottom electrodes of DRAMs' stacked capacitors. After the H3PO4 treatment and RCA cleaning process, micro-island structures are formed on the poly-Si surface of the storage electrodes, The NH4OH + H2O2 + H2O (SC-1) solution in the RCA cleaning procedures is the main component to change the porous surfaces and engraved structures, formed by H3PO4 treatment, into micro-islands. Although the electrical properties are slightly degraded compared to the control samples, but they fulfill the requirements of high-density DRAMs, resulting from the increment of cell capacitance. (C) 1997 Elsevier Science S.A.
URI: http://dx.doi.org/10.1016/S0254-0584(97)80294-5
http://hdl.handle.net/11536/149685
ISSN: 0254-0584
DOI: 10.1016/S0254-0584(97)80294-5
Journal: MATERIALS CHEMISTRY AND PHYSICS
Volume: 51
Begin Page: 195
End Page: 198
Appears in Collections:Articles