标题: | The Characteristics and Control of Body-to-Body Leakage Current in PD-SOI |
作者: | Lo, H. C. Luo, W. C. Lu, W. Y. Cheng, C. F. Chen, T. L. Lien, C. H. Fung, S. K. H. Wu, C. C. 电子工程学系及电子研究所 Department of Electronics Engineering and Institute of Electronics |
公开日期: | 2009 |
摘要: | Body-to-body leakage (BBL) current in a partially depleted silicon-on-insulator (PD-SOI) device is increased significantly as polyspacing (PS) is reduced in technology scaling. We found out that the BBL has a great impact to Vt variation. We have demonstrated that the BBL can be minimized drastically by implant optimization. The dependence of the BBL on silicon film thickness, e-SiGe structure, and dopant diffusivity is also discussed in this paper. The layout effect of the BBL current in PD-SOI devices has been characterized with different PSs, device widths, and polylengths. Finally, we have demonstrated that the BBL current can be reduced below junction leakage level. (C) 2009 The Electrochemical Society. [DOI:10.1149/1.3223971] All rights reserved. |
URI: | http://hdl.handle.net/11536/7887 http://dx.doi.org/10.1149/1.3223971 |
ISSN: | 0013-4651 |
DOI: | 10.1149/1.3223971 |
期刊: | JOURNAL OF THE ELECTROCHEMICAL SOCIETY |
Volume: | 156 |
Issue: | 11 |
起始页: | H841 |
结束页: | H845 |
显示于类别: | Articles |
文件中的档案:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.